Gastrointestinal Endoscopy - Original Article

Technical issues stemming from endoscopic-ultrasound-guided gallbladder drainage: A single center experience

Volume 30 · Issue 12 Publish Date: December 15, 2019
Full Text PDF
DOI
Yoshihide Kanno
Sendai City Medical Center, Sendai, Miyagi, Japan
Fumisato Kozakai
Sendai City Medical Center, Sendai, Miyagi, Japan
Shinsuke Koshita
Sendai City Medical Center, Sendai, Miyagi, Japan
Takahisa Ogawa
Sendai City Medical Center, Sendai, Miyagi, Japan
Hiroaki Kusunose
Sendai City Medical Center, Sendai, Miyagi, Japan
Kaori Masu
Sendai City Medical Center, Sendai, Miyagi, Japan
Toshitaka Sakai
Sendai City Medical Center, Sendai, Miyagi, Japan
Toji Murabayashi
Sendai City Medical Center, Sendai, Miyagi, Japan
Kei Ito
Sendai City Medical Center, Sendai, Miyagi, Japan
Kanno, Y., Kozakai, F., Koshita, S., Ogawa, T., Kusunose, H., Masu, K., … Ito, K. (2019). Technical issues stemming from endoscopic-ultrasound-guided gallbladder drainage: A single center experience. Turkish Journal of Gastroenterology, 30(12), 1055–1061. https://doi.org/10.5152/tjg.2019.181032
Full Text Full Text PDF

Abstract

Background/Aims: This study was conducted to evaluate the outcomes of endoscopic-ultrasound-guided gallbladder drainage (EUS-GBD) using traditional biliary stents without lumen-apposing stents and to determine technical issues. Materials and Methods: All 18 patients who underwent EUS-GBD at our center between 2012 and 2018 were evaluated. After the clinical outcomes (including technical success, clinical effectiveness, adverse events, and recurrence) were analyzed, technical countermeasures for problems extracted from the analysis were developed. Results: The rates of technical success, clinical effectiveness, severe adverse event occurrence, and recurrence of acute cholecystitis were 94% (17/18), 88% (15/17), 6% (1/18, massive bile leakage), and 27% (4/15), respectively. Distal gastrectomy causing scope instability, the non-swollen gallbladder, and double pigtail stent use caused technical difficulties. A fully covered metal stent (fcMS) should be placed in a shallow position so that it does not wedge into the opposite site. When the puncture route involves the gastric wall, the proximal portion of an fcMS located in the stomach can migrate toward the abdominal cavity. Conclusion: Although the clinical outcomes of EUS-GBD were relatively favorable, several technical issues related specifically to EUS-GBD were observed. Technical countermeasures would improve the outcomes.
Article Info
Published In
Journal Turkish Journal of Gastroenterology
Volume / Issue Volume 30 · Issue 12
Pages 1055-1061
History
Published Online December 15, 2019
Copyright
Affiliations
Yoshihide Kanno
Sendai City Medical Center, Sendai, Miyagi, Japan
Fumisato Kozakai
Sendai City Medical Center, Sendai, Miyagi, Japan
Shinsuke Koshita
Sendai City Medical Center, Sendai, Miyagi, Japan
Takahisa Ogawa
Sendai City Medical Center, Sendai, Miyagi, Japan
Hiroaki Kusunose
Sendai City Medical Center, Sendai, Miyagi, Japan
Kaori Masu
Sendai City Medical Center, Sendai, Miyagi, Japan
Toshitaka Sakai
Sendai City Medical Center, Sendai, Miyagi, Japan
Toji Murabayashi
Sendai City Medical Center, Sendai, Miyagi, Japan
Kei Ito
Sendai City Medical Center, Sendai, Miyagi, Japan
Cite this Article
Kanno, Y., Kozakai, F., Koshita, S., Ogawa, T., Kusunose, H., Masu, K., … Ito, K. (2019). Technical issues stemming from endoscopic-ultrasound-guided gallbladder drainage: A single center experience. Turkish Journal of Gastroenterology, 30(12), 1055–1061. https://doi.org/10.5152/tjg.2019.181032
Outlines